Current Transducer

MBC4000I

  • 4000 A rms nominal current
  • 5000:1 primary/secondary current ratio
  • Floating current output through 3 pin connector
  • 120 mm aperture width
  • 200 ppm (0.02%) total accuracy
  • 50 ppm linearity
  • 100 ppm offset
  • Status LED
  • Compact plastic housing with anodized alu-plate

Description

High precision DC current transducer (DCCT) measuring up to 6000 A currents and continuously measuring 4000 A currents with a linearity below 50 ppm and a maximum total error of 200 ppm. With a turns ratio of 5000:1 the MBC4000I makes high current measurement easy while providing a high accuracy, cost-effective replacement for standard hall effect based current sensors. Based on Danisense closed loop flux gate technology, the MBC4000I has a low offset and drift. It delivers high resolution for precise monitoring, reliable and consistent performance, and an easy to mount design for built-in accuracy.

Hall Effect Closed Loop
MBC4000I
Supply voltage
Hall Effect Closed Loop
± 24 V
MBC40001
± 24 V
Operating temperature
Hall Effect Closed Loop
-25 to +70
MBC40001
-40 to +85
Ratio
Hall Effect Closed Loop
5000
MBC40001
5000
Nominal DC current
Hall Effect Closed Loop
4000 A
MBC40001
4000 A
Nominal AC current
Hall Effect Closed Loop
4000 A rms
MBC40001
4000 A rms
Measuring range
Hall Effect Closed Loop
6000 A
MBC40001
6000 A
Current consumption at nominal
Hall Effect Closed Loop
0.827
MBC40001
0.9
Total error
Hall Effect Closed Loop
0.80%
MBC40001
0.05%
Offset error (primary referred)
Hall Effect Closed Loop
4 A
MBC40001
0.4 A
Temperature variation (Primary referred)
Hall Effect Closed Loop
4 A
MBC40001
0.4 A
Magnetic offset change after 3 x nominal current
Hall Effect Closed Loop
1 A
MBC40001
0.4 A
Linearity error (referred to nominal)
Hall Effect Closed Loop
0.20%
MBC40001
0.01%
Frequency bandwidth (-3dB)
Hall Effect Closed Loop
100 kHz
MBC40001
100 kHz
Aperture size
Hall Effect Closed Loop
102 mm
MBC40001
121 mm
Size (W × H × D)
Hall Effect Closed Loop
215 × 234 x 103 mm
MBC40001
218 × 238 × 89 mm
Mass
Hall Effect Closed Loop
6000 g
MBC40001
4100 g
Primary Current Rating
4000 A RMS
6000 A Peak

Total Accuracy
200 ppm

Bandwidth
100 kHz

Aperture
120 mm Max

Applications

  • High Power Solar Inverters
  • Battery Energy Storage SoC and SoH
  • Energy Metering
  • High Power Variable Frequency Drive
  • Substation Monitoring & Power Quality
  • Wind Power Inverters
  • Solid State Transformer
  • Uninterruptible Power Supply (UPS)