Stromwandler 0A bis 600A

Klicken Sie auf den Produktnamen, zu dem Sie das Datenblatt anzeigen möchten

Beachten Sie unser Benutzerhandbuch oder lesen Sie mehr über den Danisense Stromwandler
ImageProduktMessbereichBxHx (mm)Innendurchmesser(mm)RatioAusgang / AnschlussKommentar3D model
10 MHz Bandbreite
Danisense DS series current transducer 750A92x130x42252V/500ABNCStep
PCB-Montage
Danisense DP Series current transducer 72A65x32x601/250,500,1000ProgrammableStep
Faston-Anschluss
Danisense DC series current transducer 300A80×61.5×41.5201/10006.3mmx0.8mm FastonStep
DSUB Stromausgang
Danisense DS series current transducer 150A121.4×107.5×44.527.61/500DSUB9Step
75A76×64.5×3520.71/500DSUB9Step
150A76×64.5×3520.71/1000DSUB9Step
285A76×64.5×3520.71/1000DSUB9Step
Danisense DS series current transducer 370A121.4×107.5×44.527.61/500DSUB9Step
Danisense DS series current transducer 500A121.4×107.5×44.527.61/1000DSUB9Step
Danisense current transducer 600A121.4×107.5×44.527.61/2000DSUB9Step
Danisense current transducer 1000A121.4×107.5×44.527.61/1500DSUB9Step
Danisense DQ500ID current transducer 800A104x106x4728.11/1750DSUB9Step
Danisense DQ500ID current transducer 1000A104x106x4728.11/1500DSUB9Step
Danisense DQ500ID current transducer 640A104x106x4728.1Progr 40A-640ADSUB920A stepsStep
Danisense DQ500ID current transducer 1300A104x106x4728.11/1500DSUB91300A peak , 0V/+15V supplyStep
Kalibrierungswicklung in DSUB
Danisense DS series current transducer 370A121.4×107.5×44.527.61/500DSUB9Step
Danisense DS series current transducer 370A121.4×107.5×44.527.61/500DSUB9Step
Danisense DS series current transducer 1000A121.4×107.5×44.527.61/1500DSUB9Step
BNC-Spannungsausgang (2ppm/K)/b>
Danisense DS series current transducer 150A121.4×107.5×44.527.61V/50ADSUB9Step
Danisense DS series current transducer 55A121.4×107.5×44.527.610V/50ADSUB9Step
Danisense DS series current transducer 300A121.4×107.5×44.527.61V/200ADSUB9Step
Danisense DS series current transducer 220A121.4×107.5×44.527.610V/200ADSUB9Step
Danisense DS series current transducer 500A121.4×107.5×44.527.61V/300ADSUB9/BNCStep
Danisense DS series current transducer 330A121.4×107.5×44.527.610V/300ADSUB9/BNCStep
Danisense DS series current transducer 600A121.4×107.5×44.527.61V/400ADSUB9/BNCStep
Danisense DS series current transducer 440A121.4×107.5×44.527.610V/400ADSUB9/BNCStep
Danisense DS series current transducer 900A121.4×107.5×44.527.61V/600ADSUB9/BNCStep
Danisense DS series current transducer 660A121.4×107.5×44.527.610V/600ADSUB9/BNCStep