{"id":20491,"date":"2026-02-19T09:58:11","date_gmt":"2026-02-19T09:58:11","guid":{"rendered":"https:\/\/danisense.com\/documentation\/kalibrierung-toleranzen-und-messergebnisse\/"},"modified":"2026-03-31T11:39:16","modified_gmt":"2026-03-31T11:39:16","slug":"kalibrierung-toleranzen-und-messergebnisse","status":"publish","type":"documentation","link":"https:\/\/danisense.com\/de\/documentation\/kalibrierung-toleranzen-und-messergebnisse\/","title":{"rendered":"Kalibrierung &#8211; Toleranzen und Messergebnisse"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"20491\" class=\"elementor elementor-20491 elementor-20290\" data-elementor-settings=\"{&quot;element_pack_global_tooltip_width&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_padding&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true}}\" data-elementor-post-type=\"documentation\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4bf30e8 e-flex e-con-boxed e-con e-parent\" data-id=\"4bf30e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c9e6c07 elementor-widget elementor-widget-eael-breadcrumbs\" data-id=\"c9e6c07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-breadcrumbs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"eael-breadcrumbs\">\n\t\t\t<div class=\"eael-breadcrumbs__content\"><a href=\"https:\/\/danisense.com\/de\/\">Home<\/a> <span class=\"eael-breadcrumb-separator\">|<\/span> <span class = \"eael-current\">Documentation<\/span><\/div>\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c158fa8 elementor-widget__width-initial elementor-widget-tablet__width-inherit elementor-widget elementor-widget-heading\" data-id=\"c158fa8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Kalibrierung &#8211; Toleranzen und Messergebnisse<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0035141 e-flex e-con-boxed e-con e-child\" data-id=\"0035141\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-91bafe7 elementor-widget elementor-widget-heading\" data-id=\"91bafe7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Einf\u00fchrung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b21163 elementor-widget elementor-widget-text-editor\" data-id=\"8b21163\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn Kunden ISO\/IEC 17025-zertifizierte Kalibrierlaboratorien mit der Erstellung von Kalibrierberichten f\u00fcr Danisense-Stromwandler beauftragen, ist es wichtig, dass die Kunden eine aktive Entscheidung dar\u00fcber treffen, ob die Kalibrierberichte nur die gemessene Genauigkeit des Stromwandlers angeben sollen, oder ob auch Erkl\u00e4rungen \u00fcber die Konformit\u00e4t mit bestimmten Spezifikationen auf der Grundlage vordefinierter Entscheidungsregeln abgegeben werden sollen. Im letzteren Fall sind die Anforderungen an das Kalibrierungslabor in der Norm ISO\/IEC 17025 eindeutig festgelegt: <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df068ce elementor-widget elementor-widget-text-editor\" data-id=\"df068ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>&#8220;Wenn der Kunde f\u00fcr die Pr\u00fcfung oder Kalibrierung eine Konformit\u00e4tserkl\u00e4rung mit einer Spezifikation oder Norm verlangt, m\u00fcssen die Spezifikation oder Norm und die Entscheidungsregel klar definiert sein. Die gew\u00e4hlte Entscheidungsregel ist dem Kunden mitzuteilen und mit ihm abzustimmen, es sei denn, sie ist in der verlangten Spezifikation oder Norm enthalten.&#8221;<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2a2bb6 elementor-widget elementor-widget-text-editor\" data-id=\"e2a2bb6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei Danisense sind wir der Meinung, dass es in den F\u00e4llen, in denen Konformit\u00e4tserkl\u00e4rungen gem\u00e4\u00df dem obigen Absatz erforderlich sind, wichtig ist, dass der Kunde aktiv an der Definition der Toleranzspezifikation beteiligt ist, um sicherzustellen, dass der Kalibrierungsbericht den vom Kunden gew\u00fcnschten Wert hat. Wir k\u00f6nnen zwischen diesen beiden F\u00e4llen unterscheiden: <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df40c11 elementor-widget elementor-widget-text-editor\" data-id=\"df40c11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Konformit\u00e4tserkl\u00e4rungen f\u00fcr den Stromwandler werden im Hinblick auf die spezifischen Kundenanforderungen geschrieben, die sich aus der Kundenanwendung ergeben, oder<\/li><li>Die Konformit\u00e4tserkl\u00e4rungen f\u00fcr den Stromwandler beziehen sich auf die allgemeinen Spezifikationen des Datenblatts<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53c2bad elementor-widget elementor-widget-text-editor\" data-id=\"53c2bad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In beiden F\u00e4llen k\u00f6nnen Kunden, die sich aktiv f\u00fcr Spezifikationen entschieden haben, die f\u00fcr die Konformit\u00e4tserkl\u00e4rungen f\u00fcr den Messwertaufnehmer verwendet werden sollen, diese Zahlen auch verwenden, um ein Kalibrierungslabor zu w\u00e4hlen, das Kalibrierungsunsicherheiten liefern kann, die viel niedriger sind als die berechneten Spezifikationen, die f\u00fcr ihre Anwendung erforderlich sind. Letzteres hilft zu vermeiden, dass die vordefinierten Entscheidungsregeln zu nicht schl\u00fcssigen Konformit\u00e4tserkl\u00e4rungen f\u00fchren. <\/p><p>In den folgenden Abschnitten wird beschrieben, wie Sie die Toleranzspezifikationen auf der Grundlage allgemeiner Datenblattdaten berechnen k\u00f6nnen, falls der Kunde keine Spezifikationen zur Verf\u00fcgung stellen kann, die aus der speziellen Anwendung des Stromwandlers stammen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-df7ffde e-flex e-con-boxed e-con e-child\" data-id=\"df7ffde\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0d4144c elementor-widget elementor-widget-heading\" data-id=\"0d4144c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ger\u00e4tekonfigurationen f\u00fcr die Kalibrierung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-22cbc58 elementor-widget elementor-widget-text-editor\" data-id=\"22cbc58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Es gibt grunds\u00e4tzlich drei verschiedene Ger\u00e4tekonfigurationen, die kalibriert werden k\u00f6nnen.<\/p><ol><li>Stromwandler mit Stromausgang<\/li><li>Stromwandler mit Spannungsausgang<\/li><li>Stromwandler mit Stromausgang + <b>DaniSense<\/b> <b>System<\/b> <b>Interface<\/b> <b>Unit<\/b>(DSSIU) mit <b>Spannungsausgangsmodul<\/b>(VOM)<\/li><\/ol><p>Die Konfigurationsoptionen werden im folgenden Artikel sowie im Handbuch beschrieben:<\/p><p><a href=\"https:\/\/danisense.com\/wp-content\/uploads\/How-to-choose-Danisense-current-transducers-and-systeminterface-units.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/danisense.com\/wp-content\/uploads\/How-to-choose-Danisense-current-transducers-and-systeminterface-units.pdf<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-49506d7 e-flex e-con-boxed e-con e-child\" data-id=\"49506d7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-48c572f elementor-widget elementor-widget-heading\" data-id=\"48c572f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Stromwandler mit Stromausgang<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63d3f84 elementor-widget elementor-widget-text-editor\" data-id=\"63d3f84\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kalibrierlabore bieten dem Kunden oft zwischen 5 und 10 Messpunkte an. Allerdings gibt es in dieser Hinsicht keine Norm, so dass der Kunde die Messpunkte frei w\u00e4hlen kann. Es sind lediglich die technischen Randbedingungen der Laborausr\u00fcstung zu ber\u00fccksichtigen.  <\/p><p>Sobald die zu pr\u00fcfenden Stromwerte bestimmt wurden, kann die Genauigkeit gem\u00e4\u00df dem Datenblatt berechnet werden. Die Genauigkeiten f\u00fcr den DS200ID Stromsensor werden unten berechnet. Die erforderlichen Werte finden Sie auf Seite 2 des Datenblatts.  <\/p><p>Die erforderlichen Parameter sind in der folgenden Abbildung rot markiert. Die Genauigkeitsberechnung wird unten f\u00fcr ein DC-Signal durchgef\u00fchrt. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7db2938 elementor-widget elementor-widget-image\" data-id=\"7db2938\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"601\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.05-1024x769.png\" class=\"attachment-large size-large wp-image-20474\" alt=\"Abbildung 1\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.05-1024x769.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.05-300x225.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.05-768x577.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.05-600x451.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.05.png 1382w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7e1d65 elementor-widget elementor-widget-text-editor\" data-id=\"f7e1d65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tDie Berechnungsformel f\u00fcr den absoluten Fehler <sub>\ud835\udf16\ud835\udc61\ud835\udc5c\ud835\udc61<\/sub> in mA des Messwerts finden Sie auf Seite 3 des Datenblatts.\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63c65b1 elementor-widget elementor-widget-image\" data-id=\"63c65b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"266\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.24-1024x340.png\" class=\"attachment-large size-large wp-image-20475\" alt=\"\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.24-1024x340.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.24-300x100.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.24-768x255.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.24-600x199.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.24.png 1408w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf84ef5 elementor-widget elementor-widget-text-editor\" data-id=\"bf84ef5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der folgende absolute Fehler ergibt sich f\u00fcr 15 A oder 5 % des prim\u00e4ren Nennstroms DC:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25e067f elementor-widget elementor-widget-image\" data-id=\"25e067f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"768\" height=\"97\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.53-768x97.png\" class=\"attachment-medium_large size-medium_large wp-image-20476\" alt=\"\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.53-768x97.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.53-300x38.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.53-600x76.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.33.53.png 982w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd08b5a elementor-widget elementor-widget-text-editor\" data-id=\"fd08b5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Mit dieser Formel ist es m\u00f6glich, den absoluten Fehler in mA f\u00fcr alle Testpunkte zu berechnen. Die Toleranz kann auch als prozentualer Fehler definiert werden <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70d737f elementor-widget elementor-widget-image\" data-id=\"70d737f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"568\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.10-1024x727.png\" class=\"attachment-large size-large wp-image-20477\" alt=\"Tabelle 1\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.10-1024x727.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.10-300x213.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.10-768x545.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.10-600x426.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.10.png 1082w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b78e4f4 elementor-widget elementor-widget-text-editor\" data-id=\"b78e4f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Stromwandler, die auf der firmeneigenen Flux-Gate-Technologie von Danisense basieren, sind recht robuste und langlebige Produkte, aber Stress und Alterung der physikalischen Materialien w\u00e4hrend des Gebrauchs k\u00f6nnen die Leistung auf lange Sicht geringf\u00fcgig beeintr\u00e4chtigen. Bei der Kalibrierung gebrauchter Ger\u00e4te k\u00f6nnen diese Alterungsprozesse in die Toleranzgrenzen einbezogen werden. Die <q>Offset-Stabilit\u00e4t im Laufe der Zeit<\/q> k\u00f6nnen Sie dem Datenblatt entnehmen. Dieser Parameter kann auch zu dem absoluten Fehlerwert \ud835\udf16\ud835\udc61\ud835\udc5c\ud835\udc61 addiert werden<sub>.<\/sub> Dies f\u00fchrt zu einer entsprechenden Berechnungsformel.   <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88bcfba elementor-widget elementor-widget-image\" data-id=\"88bcfba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"101\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.30-768x101.png\" class=\"attachment-medium_large size-medium_large wp-image-20478\" alt=\"\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.30-768x101.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.30-300x39.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.30-600x79.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.30.png 866w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-349bd73 elementor-widget elementor-widget-text-editor\" data-id=\"349bd73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Es ist sicherlich unwahrscheinlich, dass sich der Parameter &#8220;Stabilit\u00e4t \u00fcber die Zeit&#8221; nur in eine Richtung mit dem angegebenen Maximum bewegt und somit den gr\u00f6\u00dftm\u00f6glichen Fehler erzeugt. Aus diesem Grund ber\u00fccksichtigen einige Benutzer diesen Parameter nur mit einer berechneten Wahrscheinlichkeit. Die obige Formel kann jedoch verwendet werden, um das Worst-Case-Szenario gem\u00e4\u00df dem Datenblatt zu berechnen.  <\/p><p>Um die Kommunikation mit den Kalibrierlaboratorien zu erleichtern, sollte der Kunde seine eigenen erforderlichen Toleranzwerte definieren und diese in der Bestellung f\u00fcr das Kalibrierlabor angeben. Wenn die Messwerte innerhalb dieser relevanten Toleranzwerte liegen, k\u00f6nnen die Kunden den Stromwandler weiterhin in ihrer Anwendung verwenden. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9d6faa6 e-flex e-con-boxed e-con e-child\" data-id=\"9d6faa6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-646b87c elementor-widget elementor-widget-heading\" data-id=\"646b87c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Stromwandler mit Spannungsausgang<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2cc5fdd elementor-widget elementor-widget-text-editor\" data-id=\"2cc5fdd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Um einen Spannungsausgang direkt aus dem Geh\u00e4use des Stromwandlers zur Verf\u00fcgung zu stellen, wird ein <b>Spannungsausgangsmodul<\/b>(VOM) direkt im Geh\u00e4use installiert. Das Spannungssignal kann \u00fcber ein Standard-BNC-Kabel an der BNC-Buchse mit dem jeweiligen Messinstrument verbunden werden. <\/p><p>Stromwandler mit Spannungsausgang haben in der Regel etwas h\u00f6here Fehlerwerte aufgrund der zus\u00e4tzlichen &#8211; Umwandlung des sekund\u00e4ren Strom- in ein Spannungsausgangssignal im Stromwandler selbst, die andernfalls auf der Benutzerseite mit etwa der gleichen Genauigkeitsverschlechterung durchgef\u00fchrt werden m\u00fcsste. Der eingebaute Messwiderstand f\u00fchrt auch dazu, dass die Fehlerwerte des Verh\u00e4ltnisses im Laufe der Zeit aufgrund der Drift der physikalischen Komponenten ansteigen k\u00f6nnen. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c58658 elementor-widget elementor-widget-image\" data-id=\"8c58658\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"538\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.48-768x538.png\" class=\"attachment-medium_large size-medium_large wp-image-20479\" alt=\"Abbildung 3\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.48-768x538.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.48-300x210.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.48-1024x718.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.48-600x421.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.34.48.png 1392w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d3a6035 elementor-widget elementor-widget-text-editor\" data-id=\"d3a6035\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Im Datenblatt werden diese zus\u00e4tzlichen Alterungsprozesse mit dem Parameter &#8220;Ratio stability&#8221; angegeben. Wenn also ein Ger\u00e4t, das bereits eine gewisse Zeit vom Kunden verwendet wurde, kalibriert werden muss, sollte dieser Parameter bei der Berechnung der Fehlertoleranzen ebenfalls ber\u00fccksichtigt werden. <\/p><p>F\u00fcr neue Ger\u00e4te kann das gleiche Verfahren wie f\u00fcr Stromwandler mit Stromausgang verwendet werden.<\/p><p>Formel zur Berechnung der Fehlergrenzen f\u00fcr <b>neue Ger\u00e4te<\/b> mit Spannungsausgang:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97511b5 elementor-widget elementor-widget-image\" data-id=\"97511b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"72\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.11-768x72.png\" class=\"attachment-medium_large size-medium_large wp-image-20480\" alt=\"EQ 3\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.11-768x72.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.11-300x28.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.11-600x56.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.11.png 832w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f6254b elementor-widget elementor-widget-text-editor\" data-id=\"2f6254b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Formel zur Berechnung der Fehlergrenzen der <b>verwendeten Ger\u00e4te<\/b> mit Spannungsausgang:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02563ba elementor-widget elementor-widget-image\" data-id=\"02563ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"67\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.24-768x67.png\" class=\"attachment-medium_large size-medium_large wp-image-20481\" alt=\"EQ 4\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.24-768x67.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.24-300x26.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.24-1024x89.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.24-600x52.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.35.24.png 1172w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a803209 elementor-widget elementor-widget-text-editor\" data-id=\"a803209\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wie am Ende des vorherigen Kapitels beschrieben, ist dies ein Worst-Case-Szenario. Es liegt im Ermessen des Kunden, welche Toleranzwerte er ben\u00f6tigt und wie er die Parameter &#8220;Offset-Stabilit\u00e4t \u00fcber die Zeit&#8221; und &#8220;Verh\u00e4ltnis-Stabilit\u00e4t&#8221; ber\u00fccksichtigt. Die obige Formel ist das Worst-Case-Szenario gem\u00e4\u00df dem Datenblatt.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-de70b9a e-flex e-con-boxed e-con e-parent\" data-id=\"de70b9a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-962b2fc elementor-widget elementor-widget-heading\" data-id=\"962b2fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Strommesswandler mit <b>DaniSense<\/b> <b>System<\/b> <b>Interface<\/b>Unit (DSSIU)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1be808e elementor-widget elementor-widget-text-editor\" data-id=\"1be808e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In dieser Konfiguration befindet sich das <b>Spannungsausgangsmodul<\/b>(VOM) im DSSIU-6-1U-V. Der Spannungsausgang wird \u00fcber die Mini-XLR-Buchse (3) bereitgestellt. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5c182b elementor-widget elementor-widget-image\" data-id=\"b5c182b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"495\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.10-768x495.png\" class=\"attachment-medium_large size-medium_large wp-image-20482\" alt=\"\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.10-768x495.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.10-300x193.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.10-1024x660.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.10-600x387.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.10.png 1158w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-377994f elementor-widget elementor-widget-text-editor\" data-id=\"377994f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Im Prinzip k\u00f6nnen die VOMs im DSSIU-6-1U-V ohne einen zugeh\u00f6rigen Stromwandler kalibriert werden. Dazu wird \u00fcber den D-SUB-Anschluss ein Stromsignal an den Pr\u00fcfling angelegt, das dem Stromausgangssignal des zu verwendenden Stromwandlers entspricht. Die Testpunkte werden im Voraus mit dem Kunden vereinbart.  <\/p><p>Die Toleranzwerte f\u00fcr die implementierten Module finden Sie im Datenblatt des DSSIU-6-1U-V. Achten Sie auch hier auf die Komponentendrift in VOMs und stellen Sie daher sicher, dass die Stabilit\u00e4t \u00fcber die Zeit bei den Toleranzberechnungen ber\u00fccksichtigt wurde. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed65c14 elementor-widget elementor-widget-image\" data-id=\"ed65c14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"534\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.33-1024x684.png\" class=\"attachment-large size-large wp-image-20483\" alt=\"\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.33-1024x684.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.33-300x200.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.33-768x513.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.33-600x401.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.33.png 1410w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b64ba1 elementor-widget elementor-widget-text-editor\" data-id=\"8b64ba1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bitte beachten Sie, dass sich die hier angegebenen Parameter auf die folgenden Werte beziehen.<\/p><p><strong>Offsetfehler | ppm bezieht sich auf<sub>IPN DC<\/sub><\/strong><\/p><p><strong>Verh\u00e4ltnisfehler | ppm bezieht sich auf den Messwert<\/strong><\/p><p>Es wird jedoch empfohlen, den Stromwandler in Verbindung mit der Systemeinheit zu kalibrieren. Dadurch wird die gesamte Strommesskette bis hin zum Messger\u00e4t kalibriert. In diesem Fall werden die Stromwandler den einzelnen Kan\u00e4len zugewiesen.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8f9d593 e-flex e-con-boxed e-con e-parent\" data-id=\"8f9d593\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7624137 elementor-widget elementor-widget-heading\" data-id=\"7624137\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kalibrierungsmessungen und Ergebnisse<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd19ab4 elementor-widget elementor-widget-text-editor\" data-id=\"fd19ab4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr einige Anwendungen sind Konformit\u00e4tserkl\u00e4rungen erforderlich. In diesem Fall schickt der Kunde die Strommesswandler an ein nach IEC 17025 akkreditiertes Pr\u00fcflabor, das entsprechende Genauigkeitsmessungen anbietet. Im Prinzip ist es Sache des Kunden, die erforderlichen Toleranzgrenzen (einzuhaltende Genauigkeitswerte) zu definieren. H\u00e4ufig werden die Toleranzgrenzen anhand der Datenbl\u00e4tter der Stromwandler f\u00fcr die einzelnen Messstellen berechnet und in den jeweiligen Konformit\u00e4tserkl\u00e4rungen als Entscheidungsgrundlage dokumentiert.   <\/p><p>Jedes nach IEC 17025 akkreditierte Pr\u00fcflabor muss auch die Messunsicherheit angeben, die f\u00fcr die einzelnen Messpunkte besteht. Dementsprechend werden die Messwerte oft grafisch mit der zugeh\u00f6rigen Messunsicherheit dargestellt. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08848fc elementor-widget elementor-widget-image\" data-id=\"08848fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"266\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.54-1024x341.png\" class=\"attachment-large size-large wp-image-20484\" alt=\"Abbildung 6\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.54-1024x341.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.54-300x100.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.54-768x256.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.54-600x200.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.36.54.png 1376w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9391e58 elementor-widget elementor-widget-text-editor\" data-id=\"9391e58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das obige Diagramm zeigt, dass nur die Messung A mit einer Wahrscheinlichkeit von 100 % innerhalb der Toleranzgrenzen liegt. Bei Messung B besteht das Risiko, dass der gemessene Wert aufgrund der gro\u00dfen Messunsicherheit ebenfalls au\u00dferhalb der Toleranzgrenze liegt. Dies bedeutet, dass eine falsche Entscheidung \u00fcber die Konformit\u00e4t getroffen werden kann.  <\/p><p>Um dies bei der Auswertung der Messergebnisse sichtbar zu machen, wurden &#8220;nicht-bin\u00e4re Aussagen&#8221; eingef\u00fchrt. So kann das Messergebnis B aus der obigen Abbildung mit einem &#8220;bedingten Pass&#8221; statt mit einem &#8220;Pass&#8221; bewertet werden. Diese Bezeichnung macht sofort deutlich, dass das Messergebnis eine Restwahrscheinlichkeit enth\u00e4lt, dass der Stromwandler doch au\u00dferhalb der Toleranzgrenzen liegt.  <\/p><p>Oft sind die Messunsicherheiten gr\u00f6\u00dfer als die berechneten Toleranzgrenzen des Stromwandlers. Dies kann zu &#8220;Conditional Fail&#8221;-Bewertungen f\u00fchren. Aufgrund der geringeren Messunsicherheiten in anderen Kalibrierlaboratorien besteht oft eine hohe Wahrscheinlichkeit, dass der Stromwandler trotz dieser Bewertung innerhalb der Toleranzgrenzen gem\u00e4\u00df den Spezifikationen des Datenblatts liegt.  <\/p><p>Um eindeutige bin\u00e4re Bewertungen von Laboren zu erhalten, deren Messunsicherheiten im Verh\u00e4ltnis zu den Toleranzgrenzen als hoch eingestuft werden, empfiehlt Danisense, die Messunsicherheiten bei der Berechnung der Toleranzgrenzen zu ber\u00fccksichtigen.<\/p><p>Diese Empfehlung l\u00e4sst sich am besten anhand eines realen Beispiels veranschaulichen. Ein DC-Kalibrierungsbericht der DS600ID enth\u00e4lt zum Beispiel die folgenden Messergebnisse. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83b2682 elementor-widget elementor-widget-image\" data-id=\"83b2682\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"455\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.08-1024x583.png\" class=\"attachment-large size-large wp-image-20485\" alt=\"\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.08-1024x583.png 1024w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.08-300x171.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.08-768x437.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.08-600x342.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.08.png 1370w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-194ca89 elementor-widget elementor-widget-text-editor\" data-id=\"194ca89\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die gemessene Abweichung von und einschlie\u00dflich 20 % des prim\u00e4ren Nennstroms liegt \u00fcber der im Datenblatt festgelegten Toleranz. In den oben genannten Formeln zur Berechnung der Gesamtgenauigkeit des Stromwandlers erhalten wir ein Ergebnis in A. Es ist sehr \u00fcblich, die Abweichung in % des gemessenen Wertes <sub>Ireading<\/sub> anzugeben. Mit den folgenden Formeln ist es m\u00f6glich, die positiven und negativen maximalen Toleranzwerte in % zu berechnen.  <\/p><p>Maximale Toleranzen in % der <sub>I-Ablesung<\/sub> laut Datenblatt:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-726fe11 elementor-widget elementor-widget-image\" data-id=\"726fe11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"754\" height=\"196\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.30.png\" class=\"attachment-medium_large size-medium_large wp-image-20486\" alt=\"EQ 5\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.30.png 754w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.30-300x78.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.30-600x156.png 600w\" sizes=\"(max-width: 754px) 100vw, 754px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a05dc49 elementor-widget elementor-widget-text-editor\" data-id=\"a05dc49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tIn Tabelle 2 wird die <b>Messunsicherheit<\/b> <b>(Measurement<\/b> <b>Uncertainty<\/b>, MU) auf das reale Verh\u00e4ltnis<sub>Fi<\/sub> bezogen. Um die entsprechenden Werte in Prozent zu berechnen, k\u00f6nnen die folgenden Formeln verwendet werden. \t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ba3ac6 elementor-widget elementor-widget-image\" data-id=\"5ba3ac6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"524\" height=\"104\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.46.png\" class=\"attachment-medium_large size-medium_large wp-image-20487\" alt=\"EQ 6\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.46.png 524w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.37.46-300x60.png 300w\" sizes=\"(max-width: 524px) 100vw, 524px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df40fd3 elementor-widget elementor-widget-text-editor\" data-id=\"df40fd3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Datenblatttoleranz kann nun mit der doppelten Messunsicherheit des Labors in beiden Richtungen der Y-Achse addiert werden. Die Formeln lauten wie folgt. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5862f elementor-widget elementor-widget-image\" data-id=\"0e5862f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"113\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.20-768x113.png\" class=\"attachment-medium_large size-medium_large wp-image-20488\" alt=\"EQ 7\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.20-768x113.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.20-300x44.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.20-600x88.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.20.png 802w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-496bf19 elementor-widget elementor-widget-text-editor\" data-id=\"496bf19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr einen besseren \u00dcberblick ist es sinnvoll, die gemessene Abweichung mit der berechneten Messunsicherheit anzuzeigen. Der Vollst\u00e4ndigkeit halber sollten hier auch die Formeln erw\u00e4hnt werden. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4488831 elementor-widget elementor-widget-image\" data-id=\"4488831\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"113\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.29-768x113.png\" class=\"attachment-medium_large size-medium_large wp-image-20489\" alt=\"EQ 8\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.29-768x113.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.29-300x44.png 300w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.29-600x88.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.29.png 802w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17587ec elementor-widget elementor-widget-text-editor\" data-id=\"17587ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das folgende Diagramm zeigt die Messwerte des Stromwandlers DS600ID, die vom Kalibrierlabor ab 20% des Nennstroms als &#8220;Conditional Fail&#8221; bewertet wurden. Die roten Kreuze liegen au\u00dferhalb der berechneten Toleranzwerte. Die Messunsicherheiten sind jedoch im Verh\u00e4ltnis zu den Toleranzgrenzen als hoch zu bewerten.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9bd27a elementor-widget elementor-widget-image\" data-id=\"d9bd27a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"806\" src=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.45-768x806.png\" class=\"attachment-medium_large size-medium_large wp-image-20490\" alt=\"\" srcset=\"https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.45-768x806.png 768w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.45-286x300.png 286w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.45-975x1024.png 975w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.45-600x630.png 600w, https:\/\/danisense.com\/wp-content\/uploads\/Screenshot-2025-09-16-at-13.38.45.png 1438w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cbf646e elementor-widget elementor-widget-text-editor\" data-id=\"cbf646e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die dunkelblauen Toleranzgrenzen f\u00fcr den Stromwandler wurden jeweils um das Doppelte der Messunsicherheit des Labors f\u00fcr die jeweiligen Messpunkte erh\u00f6ht. Die horizontalen gr\u00fcnen Balken stellen die angepassten Toleranzgrenzen dar. Das Kalibrierungslabor ist nun in der Lage, klare bin\u00e4re Aussagen zu machen.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-41122cf e-flex e-con-boxed e-con e-parent\" data-id=\"41122cf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e0d40c elementor-widget elementor-widget-heading\" data-id=\"6e0d40c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Besondere Aspekte der AC-Kalibrierung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-298c954 elementor-widget elementor-widget-text-editor\" data-id=\"298c954\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Berechnung der Genauigkeit von AC-Signalen erfolgt nach demselben Schema, auch wenn die Berechnungsformel f\u00fcr den Gesamtfehler DC- und AC-Effektivwerte enth\u00e4lt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f9b2b55 e-flex e-con-boxed e-con e-child\" data-id=\"f9b2b55\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-71d8d99 elementor-widget elementor-widget-button\" data-id=\"71d8d99\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/wp-content\/uploads\/Calibration-Tolerances-and-measurement-results_rev_14.pdf\" target=\"_blank\" rel=\"nofollow\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">pdf \u00f6ffnen<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Home | Einf\u00fchrung Wenn Kunden ISO\/IEC 17025-zertifizierte Kalibrierlaboratorien mit der Erstellung von Kalibrierberichten f\u00fcr Danisense-Stromwandler beauftragen, ist es wichtig, dass die Kunden eine aktive Entscheidung dar\u00fcber treffen, ob die Kalibrierberichte nur die gemessene Genauigkeit des Stromwandlers angeben sollen, oder ob auch Erkl\u00e4rungen \u00fcber die Konformit\u00e4t mit bestimmten Spezifikationen auf der Grundlage vordefinierter Entscheidungsregeln abgegeben werden [&hellip;]<\/p>\n","protected":false},"featured_media":0,"template":"","doc_category":[187],"class_list":["post-20491","documentation","type-documentation","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/danisense.com\/de\/wp-json\/wp\/v2\/documentation\/20491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/danisense.com\/de\/wp-json\/wp\/v2\/documentation"}],"about":[{"href":"https:\/\/danisense.com\/de\/wp-json\/wp\/v2\/types\/documentation"}],"version-history":[{"count":0,"href":"https:\/\/danisense.com\/de\/wp-json\/wp\/v2\/documentation\/20491\/revisions"}],"wp:attachment":[{"href":"https:\/\/danisense.com\/de\/wp-json\/wp\/v2\/media?parent=20491"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/danisense.com\/de\/wp-json\/wp\/v2\/doc_category?post=20491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}